Quick Answer
Calculate Surface-Mount Resistor Pulse Power Derating Advisor
Calculator
Result Interpretation
Surface-Mount Resistor Pulse Power Derating Advisor Calculator computes Derated Pulse Power Limit in W using the defined engineering formula and the input values provided.
Worked Example
Verified calculation
Given:
- Junction-to-Case Thermal Capacitance = 2.0E-6
- Rated Continuous Power = 0.1
- Junction-to-Case Thermal Resistance = 150
- Pulse Duration = 0.001
Expected Result:
- Derated Pulse Power Limit = 0.1439901120638
Engineering Interpretation:
Under the given input conditions, the calculated result is: Derated Pulse Power Limit = 0.1439901120638 W.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
derated pulse power limit = rated continuous power * (1 + (junction-to-case thermal resistance * junction-to-case thermal capacitance * log(1 + pulse duration / (junction-to-case thermal resistance * junction-to-case thermal capacitance))) / pulse duration)Formula family: formula_electronics_smd_resistor_pulse_power_derating_advisor
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| P_rated | Rated Continuous Power | INPUT | Rated Continuous Power |
| R_th_jc | Junction-to-Case Thermal Resistance | INPUT | Junction-to-Case Thermal Resistance |
| C_th_jc | Junction-to-Case Thermal Capacitance | INPUT | Junction-to-Case Thermal Capacitance |
| t_pulse | Pulse Duration | INPUT | Pulse Duration |
| pulse_power_limit | Derated Pulse Power Limit | OUTPUT | Derated Pulse Power Limit |
Calculation Steps
- Enter the rated continuous power in W.
- Enter the junction-to-case thermal resistance in K/W.
- Enter the junction-to-case thermal capacitance in J/K.
- Enter the pulse duration in s.
- Step 1: Compute derated pulse power limit.
- Read the derated pulse power limit (W) from the results.
Engineering Summary
Calculate Surface-Mount Resistor Pulse Power Derating Advisor
Frequently Asked Questions
What does this calculator calculate?
The Surface-Mount Resistor Pulse Power Derating Advisor Calculator estimates Derated Pulse Power Limit based on the input parameters you provide
Why is rated continuous power important in this calculation?
rated continuous power is directly proportional to derated pulse power limit. When you enter rated continuous power in W, the calculator uses it in the engineering formula to compute the output
How should I interpret the result derated pulse power limit?
The calculator outputs derated pulse power limit in W. For larger power values, divide by 1000 to express the result in kW, or by 745.7 for horsepower. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Rated Continuous Power (W), Junction-to-Case Thermal Resistance (K/W), Junction-to-Case Thermal Capacitance (J/K), Pulse Duration (s). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Browse More Tools
Explore the full index of engineering calculators on this vertical site.